Skip to content

Fix unit conversion for heat of combustion in setCustomFuelModel() - #73

Open
j-tenny wants to merge 1 commit into
firelab:masterfrom
j-tenny:fix_heat_combustion_units_conversion
Open

Fix unit conversion for heat of combustion in setCustomFuelModel()#73
j-tenny wants to merge 1 commit into
firelab:masterfrom
j-tenny:fix_heat_combustion_units_conversion

Conversation

@j-tenny

@j-tenny j-tenny commented Sep 10, 2026

Copy link
Copy Markdown

No unit conversion was happening on heat of combustion when creating a custom fuel model. Thus, if creating a custom fuel model with metric inputs, reaction intensity, spread rate, etc was off by a factor of 2.3. Added conversion for this value and tested compiling and basic run.

Same as second commit from PR #72, but was asked to separate into two PRs.

No unit conversion was happening on heat of combustion when creating a custom fuel model. Thus, if creating a custom fuel model with metric inputs, reaction intensity, spread rate, etc was off by a factor of 2.3. Added conversion for this value and tested compiling and basic run.
@shanna-h

Copy link
Copy Markdown

Hi @nwagenbrenner - would you or someone from the Fire Lab mind taking a look at this PR before we merge it? We'd appreciate any input you have from the fire science side. Thanks!

@nwagenbrenner
nwagenbrenner self-requested a review September 10, 2026 22:02
@nwagenbrenner

Copy link
Copy Markdown
Member

This looks good as well!

@shanna-h

Copy link
Copy Markdown

Great, thank you!!

@rjsheperd - Could you please also merge this one as well? Thanks!

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment